Article number vz-industrial-scientific-gasdetectie-mx6

Zoom in

Enhance gas detection capabilities with MX6 iBrid®. Monitor up to six gases simultaneously, choose from 24 sensor options, and easily adjust settings.

Description

The MX6 iBrid can detect up to six gases simultaneously using a mix of Industrial Scientific’s best monitoring technologies.

As your work changes, so does the MX6 iBrid. You can eliminate the need for multiple monitors with hundreds of sensor combinations you can easily change in the field. An internal motorized pump enables remote sampling, and an optional convertible kit allows you to detect accurate benzene levels. The MX6 iBrid provides the advanced gas detection you need for sampling and permitting tasks and excels in industries such as oil and gas, petrochemicals, and metal production.

Gases detected: LEL (methane), LEL (pentane), PID, IR, Cl2, ClO2, CO, CO high, CO/H2 low, CO/H2S, H2, H2S, HCL, HCN, NH3, NO, NO2, O2, PH3, PH3 high, SO2.

The MX6 iBrid must be equipped with an SP6 Pump and photoionization detector (PID) to detect benzene gas.

The MX6 utilizes all field replaceable, plug-in sensors. The user can replace any sensor in the field and have the instrument in service after performing a simple field calibration.

Oxygen sensors in the MX6 iBrid will typically last two years. On average, toxic sensors will last 3-4 years and combustible sensors 4-5 years. There is no need to replace these sensors before they indicate a marginal or failed calibration in the MX6.

The catalytic bead combustible gas sensor in the MX6 iBrid requires a minimum of 10% oxygen to provide an accurate reading. In any situation in which the oxygen reading is less than 10%, the combustible gas reading must be considered to be in error. The MX6 can also utilize one of two infrared (IR) sensors to detect combustible gas to 100% LEL or methane to 100% of volume. The infrared sensors do not rely on oxygen and therefore function accurately in an oxygen-deficient atmosphere. It must be noted that the infrared sensors will not respond to hydrogen.

In applications in which hydrogen is present and there is less than 10% oxygen, a 1:1 dilution fitting must be used in the sample line to provide sufficient oxygen to the sensor and get an accurate reading. When using a dilution fitting, the user must always remember that the monitor will display one-half of the actual gas concentration being measured.

As a general rule, the MX6 iBrid with pump is rated to sustain a continuous sample draw for up to 100 feet with 0.125-inch inside diameter sample tubing. However, the pump will provide adequate flow at 0.5 liters per minute up to a vacuum pressure of approximately 30 inches of H2O. The length of the sample tube can exceed 100 feet as long as the vacuum pressure required to draw the sample does not exceed 30 inches of H2O.

Warranty: The MX6 iBrid comes with our Guaranteed for Life™ warranty. The monitor is warranted for as long as the monitor is supported by Industrial Scientific Corporation.

Power Source and Run Times

  • Source 1: Rechargeable extended-range lithium-ion battery (36 hours) without pump
  • Source 2: Rechargeable extended-range lithium-ion battery (20 hours) with pump
  • Source 3: Replaceable AA alkaline battery (10.5 hours) without pump

Temperature Range: -20 °C to 55 °C (-4 °F to 131 °F)

Humidity Range: 15-95% non-condensing (continuous)

Read more

Specifications

Article number vz-industrial-scientific-gasdetectie-mx6
Brand Industrial Scientific
Order quantity per 1

Range MX6 iBrid®

Gas sensors HCI
Gas sensors CI2
Gas sensors CIO2
Gas sensors Carbon monoxide (CO)
Gas sensors CO2 IR
Gas sensors CO/H2 Low
Gas sensors CO/H2S
Gas sensors CO/High
Gas sensors Combustible IR (0-100%LEL)
Gas sensors H2
Gas sensors H2S
Gas sensors HCN
Gas sensors LEL (Methane)
Gas sensors LEL (Pentane)
Gas sensors Methane (0-5%)
Gas sensors Methane IR (0-100%LEL)
Gas sensors Methane IR (0-100%Vol)
Gas sensors NH3
Gas sensors Nitric oxide (NO)
Gas sensors Nitrogen dioxide (NO2)
Gas sensors Oxygen (O2)
Gas sensors PH3
Gas sensors PH3 High
Gas sensors PID
Gas sensors SO2
Colour black
Maximum operating temperature 55 °C
Maximum operating humidity 15 % RH
Minimum operating humidity 95 % RH
Minimum operating temperature -20 °C
customer service representative